- Testing Equipment[10]
- Other Electronic Measuring Instruments[5]
- Voltage Meters[1]
- Other Electrical Instruments[1]
- Electronic & Instrument Enclosures[1]
- Power Distribution Equipment[1]
- Other Generators[1]
- Transformers[2]
- Switching Power Supply[1]
- Alternative Energy Generators[1]
- Resistance Meters[1]
- Current Meters[1]
- Electrical Ceramics[1]
- Contact Person : Ms. LYU lisa
- Company Name : Wuhan Huatian Electric Power Automation Co., Ltd.
- Tel : 86-27-87457960
- Fax : 86-27-87803129
- Address : Hubei,Wuhan,No. 27, Guanshan Road, Hongshan Area, Wuhan, Hubei Province, P.R.China
- Country/Region : China
- Zip : 430074
FY-H transformer load box
transformer load box ,CT load box, PT load box
FY series current, voltage transformer load box supply various real load when test current or voltage transformer, it is the ideal auxiliary product for transformer detectors. It is strictly designed according JJG313-94<current transformer verification regulation>,JJG314-94<voltage transformer verification regulation>, it is with advantages of large output capacity, great variety of load, light weight, beautiful outlook, strong stability, etc.
product features
Light weight, beautiful outlook, high capacity and strong stability,
product parameters
1.FY96-H current transformer load box
Main technique parameters
condition of circumstance
temperature: 15-25°C humidity: <80%(25°C)
humidity: <1500m frequency:50Hz
rated capacity: COS0.8: 2.5VA-60VA; COS1.0: 2.5VA-20VA;
measurement range:
current: 1%-120%
secondary current:5A
power factor:0.8, 1.0
accuracy: ±3%±0.0025VA
test voltage:2KV
dimension: 250 mm×350 mm×175 mm
weight:8kg
2. FY96-A current transformer load box
Main technique parameters
condition of circumstance
temperature: 15-25°C humidity: <80%(25°C)
humidity: <1500m frequency:50Hz
rated capacity: COS0.8: 2.5VA-60VA; COS1.0: 2.5VA-20VA;
measurement range:
current: 5%-120%
secondary current:1A
power factor:0.8, 1.0
accuracy: ±3%±0.0025VA
test voltage:2KV
dimension: 250 mm×350 mm×175 mm
weight:8kg
3. FY95-H voltage transformer load box
Main technique parameters
condition of circumstance
temperature: 15-25°C humidity: <80%(25°C)
humidity: <1500m frequency:50Hz
rated capacity: 1.25VA-158.75VA
measurement range:20%-120%
secondary voltage:110/ V
power factor:0.8, 1.0
accuracy: ±3%±0.05VA
test voltage:2KV
dimension: 250 mm×350 mm×175 mm
weight:8kg
4. FY95-A voltage transformer load box
Main technique parameters
condition of circumstance
temperature: 15-25°C humidity: <80%(25°C)
humidity: <1500m frequency:50Hz
rated capacity: 1.25VA-158.75VA
measurement range:20%-120%
secondary voltage:110/ V
power factor:0.8, 1.0
accuracy: ±3%±0.05VA
test voltage:2KV
dimension: 250 mm×350 mm×175 mm
weight:8kg
5. FY98-H current voltage transformer load box
Main technique parameters
condition of circumstance
temperature: 15-25°C humidity: <80%(25°C)
humidity: <1500m frequency:50Hz
rated capacity:
current :COS0.8: 2.5VA-60VA; COS1.0: 2.5VA-5VA;
voltage: 1.25VA-158.75VA
measurement range:
current: 1%-120% voltage: 20%-120%
secondary current:1A
secondary voltage:110/ V
power factor:0.8, 1.0
accuracy:
current: ±3%±0.0025VA voltage: ±3% ±0.05VA
test voltage:2KV
dimension: 340 mm×350 mm×175 mm
weight:15kg
6. FY98-A current voltage transformer load box
Main technique parameters
condition of circumstance
temperature: 15-25°C humidity: <80%(25°C)
humidity: <1500m frequency:50Hz
rated capacity:
current :COS0.8: 2.5VA-60VA; COS1.0: 2.5VA-5VA;
voltage: 1.25VA-158.75VA
measurement range:
current: 5%-120% voltage: 20%-120%
secondary current:1A
secondary voltage:110/ V
power factor:0.8, 1.0
accuracy:
current: ±3%±0.0025VA voltage: ±3% ±0.05VA
test voltage:2KV
dimension: 340 mm×350 mm×175 mm
weight:15kg
FY-H transformer load box