SMG2000B Double Clamp Digital Phase Meter
clamp phase meter, clamp phase meter, digital clamp phase meter
Products features
1. Withstand Voltage
Parts between voltage input terminal and meter shell, parts between the iron core of the clamp-current transformer and secondary windings can stand 1000V/50Hz. Parts between the two voltage input terminals can stand Sinusoidal AC Voltage 500V/50Hz for 1min when testing.
2. Insulation Resistance
Between meter circuit and meter shell, between the two voltage input terminals≥10MΩ
Technical Specifications
Intrinsic Error
1. Reference Operating Conditions
(1)Temperature(23±5)°C
(2)Moisture(45~75)% RH
(3)Wave forms of measured signal, sine wave,β=0.02
(4)Frequency of measured signal(50±0.2)Hz
(5)Position of Measured current carrying conductor in the nipper jaw, Optional position
(6)Amplitude range of measured signal when measuring phase,100~220V,0.5A~1.5A
(7)External reference frequency electromagnetic interference, Should be avoided
2 . Limits of Intrinsic Error
(1 )AC Voltage(see Table 1)
Table 1 Error of AC Voltage | ||
Measure range | Resolution | Limits of intrinsic error |
20V | 0.01V | ±(1.2%RD+2) |
200V | 0.1V | ±(1.0%RD+2) |
500V | 1V | ±(1.2%RD+2) |
Input Impedance, All the measure range is 2MΩ
(2) Alternating current(see Table 2)
Table 2 Error of alternating current | ||
Measure range | Resolution | Limits of intrinsic error |
200mA | 0.1mA | ±(1.0%RD+2) |
2A | 1mA | |
10A | 10mA |
(3) Phase
U-U,U-I,I-I(see Table 3)
Table 3 Error of Power-frequency Phase | ||
Range | Resolution | Limits of intrinsic error |
0~360° | 1° | ±3° |
Impedance of input voltage loop when measuring phase of U1-U2, 40KΩ
Operating error
1.Rated Operating Conditions
(1)Temperature (0~40)°C
(2)Moisture (20~80)% RH
(3)Wave forms of measured signal, sine wave,β=0.05
(4)Frequency of measured signal,(50±0.5)Hz
(5)(5)Position of Measured current carrying conductor in the nipper jaw, Optional position.
(6)Amplitude range of measured signal when measuring phase,
Phase U1-U2, 30V~500V
Phase I1-I2, 10mA~10.00A
Phase U1-I2 or I1-U2, 10V~500V,10mA~10.00A
(7)External reference frequency electromagnetic interference, should be avoided
2 . Limits of Rated Operating Error
Under the conditions described in 1, the limits of the rated operating error will not exceed twice of the limits of intrinsic error.
Other Technical Features
1 .Display, three and half
2. Sampling Rate, 3 times per second
3.Power Supply, Single 9V laminated cell,current of power is less than 5mA
4. Dimension
Meter shell, 192x95x55mm
Nipper shell, 140×42×20mm
Nipper jaw, Φ7×9mm
5. Weight
Meter body, 280g
Measuring pliers, 2×200g
6. Storage Conditions
Temperature, -10°C~50°C
SMG2000B Double Clamp Digital Phase Meter